EICR in Scotland: how often does a landlord need an electrical inspection?

Last reviewed 13 November 2026

The short answer

In Scotland, a private landlord needs an electrical safety inspection before a tenancy starts and then at intervals of no more than five years. The inspection is an Electrical Installation Condition Report (EICR) on the fixed wiring, plus portable appliance testing (PAT) on appliances the landlord provides. If the electrician recommends a shorter interval, the landlord must follow that advice.

You may see this called an EICR certificate or an electrical safety certificate. The document the electrician issues is a report: an Electrical Installation Condition Report.

This comes from the Scottish Government’s statutory guidance on the Repairing Standard. An inspection done in the five years before a new tenancy starts can be used, so you do not need a new EICR every time a tenant changes.

What the inspection covers

  • The EICR covers the fixed electrical installation: the wiring, sockets, light fittings, switches and the consumer unit.
  • PAT covers portable equipment you supply, such as white goods, kettles and other small appliances. It does not cover appliances the tenant owns. PAT results are recorded in a separate register from the EICR.
  • The guidance says landlords must check that any second-hand equipment they provide is safe.
  • Five years is the longest allowed gap. The guidance notes that the PAT retest date is usually set during testing and is often sooner than five years, and an EICR may recommend a shorter interval too.

If you have an Electrical Installation Certificate (EIC), for example after a rewire, the guidance says you can use it instead of an EICR, as long as it was issued no more than five years ago and the next inspection date on it has not passed.

Who can carry it out

The guidance says the EICR must be completed by a skilled person who is competent to do the work. It gives membership of a scheme run by SELECT, NICEIC or NAPIT as acceptable evidence. An electrician outside those schemes needs to meet the competence checklist in the guidance. PAT can be carried out by a skilled person or by someone with appropriate training.

Understanding the codes

An EICR lists any problems with a classification code. The guidance explains what each one means for a landlord:

EICR classification codes and what the guidance says
C1Danger present. Anyone using the installation is at risk.Must be put right. Work should be done immediately.
C2Potentially dangerous.Must be put right. Urgent remedial action is required.
C3Improvement recommended. Not an immediate danger.Not necessarily required, but landlords should consider it.
FIFurther investigation needed.Should be investigated as soon as practically possible.

The guidance says repair work done to put right defects should be recorded separately, and that an EIC must be provided if a consumer unit is replaced. Any equipment that fails PAT must be replaced or repaired immediately.

Residual current devices

The Repairing Standard requires one or more residual current devices (RCDs), rated at no more than 30 mA, in the main consumer unit. The guidance says a house without an RCD does not comply with the Repairing Standard. If you are not sure whether your consumer unit has one, ask your electrician at the next inspection.

Copies for tenants and keeping records

  • Give a prospective tenant a copy of the most recent EICR before the tenancy starts.
  • If an inspection is carried out during a tenancy, give the tenant a copy of that report.
  • The guidance says the landlord must keep a copy of the EICR for six years.
  • Tenants cannot be made to pay towards the electrical safety inspection, unless the First-tier Tribunal orders it.

Step by step for each property

  1. Find the date of the last inspection

    Check the date on the current EICR, or on an EIC if the property was rewired. Work out when five years is up.

  2. Check the recommended date

    The report gives a recommended date for the next inspection. If it is sooner than five years, that is the date to work to.

  3. Book a skilled electrician

    Ask for an EICR on the fixed installation and PAT on the appliances you provide, so both are covered.

  4. Put right C1 and C2 items

    Keep the electrician’s record of the remedial work with the report, so you can show what was fixed and when.

  5. Give the tenant a copy and record the next date

    Note when and how you gave the tenant the report, and set a reminder for the next inspection.

The electrical inspection is one of several checks for a rental in Scotland. See what certificates a landlord needs in Scotland for the full list, and landlord gas safety certificates for the annual gas check.

Official sources

This guide is general information about keeping records. It is not legal, safety or technical advice. MyPropertyRecord stores the records and dates you enter; it does not check or determine whether a property meets any legal requirement. Requirements differ across England, Scotland, Wales and Northern Ireland, and by property type, use and tenancy, and they change. Where this guide mentions a legal duty, check the current official guidance linked on this page before relying on it.