What certificates does a landlord need in Scotland?
Last reviewed 13 November 2026
The short answer
The landlord certificates and checks a private landlord in Scotland usually needs are: an annual gas safety record (if the property has gas), an Electrical Installation Condition Report (EICR) and portable appliance testing (PAT) at least every five years, interlinked smoke and heat alarms with carbon monoxide detectors where needed, a legionella risk assessment reviewed at least every two years, and an Energy Performance Certificate (EPC). You must also be registered as a landlord and protect any deposit in an approved scheme.
Most of the safety requirements come from the Repairing Standard, which the Scottish Government explains in its statutory guidance for private landlords. The details below are a summary of that guidance and the other official pages linked on this page.
People sometimes search for a “landlord maintenance certificate”. This guide uses the names the Scottish Government guidance gives to each document, as listed in the table below.
Safety checks and how often
| Check | How often | Who does it, and what to give the tenant |
|---|---|---|
| Gas safety check | Every 12 months, for each gas appliance and flue | A Gas Safe registered engineer. Give existing tenants a copy of the record within 28 days of the check, and new tenants a copy before the tenancy starts. |
| Electrical Installation Condition Report (EICR) | Before a tenancy starts, then at intervals of no more than five years, or sooner if the electrician recommends it | A skilled, competent person, such as a member of SELECT, NICEIC or NAPIT. Give a prospective tenant a copy of the most recent EICR before the tenancy starts. |
| Portable appliance testing (PAT) | As part of the same electrical safety inspection, at least every five years; the tester often sets an earlier retest date | Covers appliances you provide, such as white goods and kettles, but not appliances the tenant owns. |
| Smoke, heat and carbon monoxide alarms | An ongoing requirement; replace each smoke and heat alarm every 10 years, as the Scottish Fire and Rescue Service advises | An interlinked system of smoke and heat alarms, and a carbon monoxide detector in every room with a fixed combustion appliance or a flue. |
| Legionella risk assessment | Before the property is first let, then reviewed at intervals of no more than two years | You may be able to do it yourself; some water systems need a competent assessor. Tell tenants about the control measures. |
Gas safety
The guidance says landlords must keep gas fittings and flues safe and arrange an annual safety check of each gas appliance and flue. The check can be done up to two months before it is due while keeping the original due date, as long as you can show the checks met the required timescale. Any defect must be repaired by a Gas Safe registered engineer. See landlord gas safety certificates for the details of the record.
Electrical safety
The guidance treats the EICR and PAT as one electrical safety inspection. An inspection carried out in the five years before a tenancy starts can be used, so you do not need a new one for every tenancy. Items coded C1 or C2 in the report must be put right. There is more on codes, electricians and residual current devices in EICR in Scotland: how often a landlord needs one.
Fire and carbon monoxide alarms
Every home in Scotland must have interlinked smoke and heat alarms, and the requirement is part of the Tolerable Standard, which applies to all tenures. The guidance says private landlords must fit carbon monoxide detectors in every room with a fixed combustion appliance, such as a boiler, fire, heater or stove, that runs on gas, oil or solid fuel, or that has a flue. Appliances used only for cooking are excluded. See interlinked smoke and heat alarms in Scotland for where each alarm goes.
Legionella
Landlords must assess the risk from legionella in the hot and cold water systems before the property is first let, and review it at intervals of no more than two years. The guidance lists control measures landlords must take, including flushing the system before letting if it has not been flushed in the previous two years, keeping a tight-fitting lid on any cold water tank, storing hot water at 60°C or above, and removing redundant pipework.
Registration, deposits and the EPC
Landlord registration
- You must register as a landlord before you rent out a property, unless you are exempt, and renew the registration every three years. Anyone who owns the property with you must register too.
- mygov.scot says renting out a property without registration is a criminal offence, with a fine of up to £50,000.
- Adverts must include your landlord registration number, or the words “landlord registration pending” while your application is being processed.
- There are exemptions, for example for resident landlords and for renting to family members. Holiday lets may need a short-term let licence instead.
Tenancy deposits
- You can ask for a deposit of up to two months’ rent.
- You must protect the deposit in one of three approved schemes within 30 working days of the tenancy starting: Letting Protection Service Scotland, mydeposits Scotland or SafeDeposits Scotland.
- Within 30 days of the tenancy starting, you must tell the tenant in writing the property address, the deposit amount and date received, the date it was paid into the scheme, the scheme’s name and contact details, your landlord registration status, and when you might keep some or all of the deposit.
- If you do not protect the deposit, the tenant can apply to the First-tier Tribunal for Scotland, which can order you to pay them up to three times the deposit.
Energy Performance Certificate (EPC)
- Each rented home needs an EPC, which is valid for up to 10 years. A room let with shared facilities does not need its own.
- Give new tenants a copy of the EPC and its recommendations report, free of charge. Tenants renewing a lease do not need a new copy.
- Adverts in commercial media must show the EPC rating.
A checklist for each property
Use this to see what you have on file for each rental. Each line is a document or date worth keeping, not a statement that the property meets the law.
Certificates and reports
- Current gas safety record, with the date of the next check
- Current EICR, with the date the electrician recommends for the next inspection
- PAT record for the appliances you provide
- Legionella risk assessment, with the date of the next review
- EPC and recommendations report
Alarms
- Where each smoke, heat and carbon monoxide alarm is, its make and model, and when it was fitted
- The date each alarm is due to be replaced
Registration and tenancy
- Landlord registration number and renewal date
- Deposit scheme name, the date the deposit was protected and a copy of the information you gave the tenant
- Dates you gave the tenant copies of the gas safety record, EICR and EPC
Keeping the records
- Keep each gas safety record for at least two years. If you have checks done up to two months early, keep each record until two further checks have been carried out.
- The guidance says landlords must keep a copy of the EICR for six years.
- Record repair work after a check, such as gas defects put right or C1 and C2 electrical items fixed, alongside the report it relates to.
- Note the date you gave each document to the tenant, and how. It is the easiest way to show it was done.
For a wider view of what to file for a rental, see what records a landlord should keep.
England, Wales and Northern Ireland
Gas safety checks follow similar rules across the UK, but electrical safety, alarms, registration and deposits are handled differently in each nation. If you let property outside Scotland, start with what records a landlord should keep, which sets out the differences, and check the official guidance for that nation.
Official sources
- gov.scot: Repairing Standard statutory guidance for private landlords
- gov.scot: Repairing Standard guidance, installations for the supply of electricity
- gov.scot: Repairing Standard guidance, installations for the supply of gas
- gov.scot: Repairing Standard guidance, installations for the supply of water (legionella)
- gov.scot: fire and smoke alarms, the law
- HSE: gas safety check records and what to keep
- mygov.scot: landlord registration
- mygov.scot: protecting a tenancy deposit
- gov.scot: Energy Performance Certificates, buildings for let
Related guides
- EICR in Scotland: how often does a landlord need an electrical inspection?
The five-year electrical inspection for Scottish rentals: EICR and PAT, electricians, codes, RCDs and copies for tenants.
- Landlord gas safety certificate: how often, how long it lasts and what to do with it
The annual gas safety check: what it covers, early checks, copies for tenants, what the record includes and how long to keep it.
- Smoke and fire alarm regulations in Scotland: what the law requires
Where each smoke, heat and carbon monoxide alarm goes in a Scottish home, and who is responsible for fitting them.
This guide is general information about keeping records. It is not legal, safety or technical advice. MyPropertyRecord stores the records and dates you enter; it does not check or determine whether a property meets any legal requirement. Requirements differ across England, Scotland, Wales and Northern Ireland, and by property type, use and tenancy, and they change. Where this guide mentions a legal duty, check the current official guidance linked on this page before relying on it.